Configuración - Bloquer EMMs

elgeneral

Registered
Messages
7,811
Translation ENG

Hello all,

Setting Up the Blocker for Local Mode, example using a SECA CARD:

Código:
[11223344]
ok_view=1
emm=6


Setting up the Blocker in Client Mode using Newcamd Protocol:

Código:
server0=dummy:dummy@4578:3666/0102030405060708091011121314/2

Setting up the blocker em Server Mode using Newcamd Protocol:

Código:
[slot0]
active=0
sci=/dev/sci0
ncdserver=1
deskey=0102030405060708091011121314
port=15051
users=dummy:dummy:1,dummy1:dummy1:0

[11223344] #(This is the Card inserted in /dev/sci0)
ok_view=1
emm=6

How to know the meaning of each value?

Código:
0=Accepts all EMMs
1=Ignore the EMM-S
2=Ignore the EMM-U
4=Ignore the EMM-G

An example, if you want to ignore the EMM-S and the EMM-U, then the correct value would be the summ of (1+2=3). If you want to block only the EMM-S and EMM-G, would be 1+4=5, then the correct value would be 5.

Regards EDK

Si se omite la configuración del bloquer, SBox por defecto bloqueará todas las EMM.

Antes de nada hay que averiguar el nº de serie de nuestra tarjeta, la mejor forma es ejecutando sbox desde telnet y fijarse en el dato que marco de color rojo:
Code:
========================================================
 [Init] ID: 0x00 | Serial: 0x[COLOR="red"]11223344[/COLOR] | System: Seca
========================================================


Configurando el bloquer para modo local, ejemplo usando una tarjeta seca:
Code:
[[COLOR="red"]11223344[/COLOR]]
ok_view=1
[U]emm=6[/U]


Configurando el bloquer en modo cliente newcamd:
Code:
server0=dummy:dummy@4578:3666/0102030405060708091011121314/[U]2[/U]


Cómo saber que significa cada valor?
Code:
0=Acepta todas las EMMs
1=Ignora las EMM-S
2=Ignora las EMM-U
4=Ignora las EMM-G


Si por ejemplo se quieren ignorar las EMM-S y las EMM-U, el valor correcto sería la suma de estos (1+2=3). Que se quieren bloquear las EMM-S y las EMM-G, pues 1+4=5, el valor para el bloquer sería 5.


Saludos EDK
 
Top